SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Rajapakse BN, Thiermann H, Eyer P, Worek F, Bowe SJ, Dawson AH, Buckley NA. Ann. Emerg. Med. 2011; 58(6): 559-564.e6.

Affiliation

South Asian Clinical Toxicology Research Collaboration, Peradeniya, Sri Lanka; ANU Medical School, Australian National University, Canberra, Australia; Emergency Department, Prince of Wales Hospital, Sydney, Australia.

Copyright

(Copyright © 2011, American College of Emergency Physicians, Publisher Elsevier Publishing)

DOI

10.1016/j.annemergmed.2011.07.014

PMID

22098995

Abstract

STUDY OBJECTIVE: Measurement of acetylcholinesterase (AChE) is recommended in the management of organophosphorus poisoning, which results in 200,000 deaths worldwide annually. The Test-mate ChE 400 is a portable field kit designed for detecting occupational organophosphorus exposure that measures RBC AChE and plasma cholinesterase (PChE) within 4 minutes. We evaluate Test-mate against a reference laboratory test in patients with acute organophosphorus self-poisoning. METHODS: This was a cross-sectional comparison study of 14 patients with acute organophosphorus poisoning between May 2007 and June 2008. RBC AChE and PChE were measured in 96 and 91 samples, respectively, with the Test-mate ChE field kit and compared with a reference laboratory, using the limits of agreement method (Bland and Altman), κ statistics, and Spearman's correlation coefficients. RESULTS: There was good agreement between the Test-mate ChE and the reference laboratory for RBC AChE. The mean difference (Test-mate-reference) was -0.62 U/g hemoglobin, 95% limits of agreement -10.84 to 9.59 U/g hemoglobin. Good agreement was also observed between the categories of mild, moderate, and severe RBC AChE inhibition (weighted κ 0.85; 95% confidence interval [CI] 0.83 to 0.87). Measurement of PChE also showed good agreement, with a mean difference (Test-mate-reference) of +0.06 U/mL blood, 95% limits of agreement -0.41 to 0.53 U/mL blood. Spearman's correlation coefficients were 0.87 (95% CI 0.81 to 0.91) for RBC AChE and 0.76 (95% CI 0.66 to 0.84) for PChE. Analysis for within-subject correlation of subjects did not change the limits of agreement. CONCLUSION: The Test-mate ChE field kit reliably provides rapid measurement of RBC AChE in acute organophosphorus poisoning.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print