SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Lutmer B, Zurfluh C, Long C. J. Anal. Toxicol. 2009; 33(3): 167-169.

Affiliation

Missouri Department of Health and Senior Services, State Public Health Laboratory, Breath Alcohol Program, 2875 James Blvd., Poplar Bluff, Missouri 63901.

Copyright

(Copyright © 2009, Preston Publications)

DOI

unavailable

PMID

19371466

Abstract

Since the advent of energy drinks in the U.S. marketplace, some defendants have claimed that positive breath alcohol test results have occurred due to the ingestion of non-alcoholic energy drinks. A variety of energy drinks were tested by gas chromatography and some 88.9% (24 of 27) were found to contain low concentrations of ethanol (5-230 mg/dL). Drinks were then consumed (24.6-32 oz) by volunteers to determine the extent of reaction that could be achieved on a portable breath-testing instrument. Eleven of 27 (40.7%) beverages gave positive results on a portable breath-testing instrument (0.006-0.015 g/210 L) when samples were taken within 1 min of the end of drinking. All tests taken by portable breath test, DataMaster, and Intox EC/IR II at least 15 min after the end of drinking resulted in alcohol-free readings (0.000 g/210 L). Affording subjects a minimum 15-min observation period prior to breath-alcohol testing eliminates the possibility that a small false-positive alcohol reading will be obtained.


Language: en