Mikolajczak CJ, Taylor PM. J. Burn Care Res. 2008; 29(2): 338-345.

Affiliation

Exponent Failure Analysis Associates, Menlo Park, California.

Copyright

(Copyright © 2008, American Burn Association, Publisher Lippincott Williams and Wilkins)

DOI

10.1097/BCR.0b013e318166797c

PMID

18354291

Abstract

We developed an approach to adapt the ASTM C1055-03 Standard to assess the potential for contact burn injury from portable consumer electronic devices. The approach involves measuring the maximum temperature profile during the fault and devising a way to reproduce these temperatures in an exemplar device in a controlled manner for thermesthesiometer measurements. By comparing the results of the thermesthesiometer measurements to the contact burn injury threshold data published in ASTM C1055-03 and various guidelines for unintentional contact times, we were able to predict whether a potential hazard exists and verify result with"finger tests."We applied this method on a number of occasions to assess the likelihood of a contact burn injury resulting from a fault arising inside portable consumer electronic devices.