SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Donelan JM, Li Q, Naing V, Hoffer JA, Weber DJ, Kuo AD. Science 2008; 319(5864): 807-810.

Affiliation

School of Kinesiology, Simon Fraser University (SFU), Burnaby, BC V5A 1S6, Canada. mdonelan@sfu.ca

Copyright

(Copyright © 2008, American Association for the Advancement of Science)

DOI

10.1126/science.1149860

PMID

18258914

Abstract

We have developed a biomechanical energy harvester that generates electricity during human walking with little extra effort. Unlike conventional human-powered generators that use positive muscle work, our technology assists muscles in performing negative work, analogous to regenerative braking in hybrid cars, where energy normally dissipated during braking drives a generator instead. The energy harvester mounts at the knee and selectively engages power generation at the end of the swing phase, thus assisting deceleration of the joint. Test subjects walking with one device on each leg produced an average of 5 watts of electricity, which is about 10 times that of shoe-mounted devices. The cost of harvesting-the additional metabolic power required to produce 1 watt of electricity-is less than one-eighth of that for conventional human power generation. Producing substantial electricity with little extra effort makes this method well-suited for charging powered prosthetic limbs and other portable medical devices.