SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Liu T, Mu X, Wu X, Jia R, Xie J, Gao Z. Sci. Rep. 2023; 13(1): e14804.

Copyright

(Copyright © 2023, Nature Publishing Group)

DOI

10.1038/s41598-023-42117-x

PMID

37684348

Abstract

The ignition and explosion processes of suspended coal dust clouds and their suppression characteristics are important aspects of dust prevention and control. To understand the ignition temperature and explosion pressure of coal dust clouds, as well as the inhibitory effect of explosion suppressants, experimental tests are conducted. The study found that during the ignition process of coal dust clouds, the optimal dust spray pressure is 20 kPa, because coal dust clouds are more likely to ignite under this condition. When the mass concentration of coal dust cloud is 500 g m(-3), the maximum pressure and maximum pressure rise rate are both the highest. When Al(OH)(3) is mixed with coal dust and the mass percentage is 60%, the coal dust cloud can still be ignited. When KH(2)PO(4) is mixed with coal dust, the upper limit of the test temperature is reached when the percentage of mixture is 55%. When NH(4)H(2)PO(4) is mixed with coal dust and the mass percentage is greater than 40%, the coal dust cloud can't be ignited anymore. The suppression effect of mixing Al(OH)(3) and NH(4)H(2)PO(4) is not as good as that of mixing KH(2)PO(4) and NH(4)H(2)PO(4).


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley