SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Prasertwitayakij N, Komolmis T, Gunaparn S, Pisespongsa C, Phrommintikul A, Wongcharoen W, Nantsupawat T. Expert Rev. Med. Devices 2023; ePub(ePub): ePub.

Copyright

(Copyright © 2023, Informa Healthcare)

DOI

10.1080/17434440.2023.2255126

PMID

37668539

Abstract

INTRODUCTION: The automobile passive keyless entry (PKE) system is a potential source of electromagnetic interference (EMI). We aim to determine the incidence and significance of EMI from automobile PKE system in cardiovascular implantable electronic device (CIED) patients.

METHODS: This was a single-center cross-sectional study conducted at Maharaj Nakorn Chiang Mai hospital, Thailand. Patients with CIED were instructed to lock and unlock two automobiles using the PKE system. Any EMI or arrhythmias were detected by CIED interrogation and single-lead electrocardiogram event recorder. We also used a spectrum analyzer to identify the automobiles working frequency bandwidth.

RESULTS: There was a total of 102 CIED patients. Device types included 48.0% defibrillators, 37.3% permanent pacemakers, and 14.7% cardiac resynchronization therapy device. Both interrogated data from device and event monitor revealed no incidence of EMI during the PKE activation. We failed to identify the working frequency bandwidth of the two studied cars due to very low signal strength, thus blended in with the background noise.

CONCLUSIONS: Automobile PKE systems transmitted very low power signals. Therefore, under normal circumstances, CIED patients can use automobile PKE system safely without any EMI regardless of key fob positions in relation to the CIED pulse generator. TRIAL REGISTRATION: The study was registered at ClinicalTrials.gov (https://clinicaltrials.gov), and the identification number is NCT03016390.


Language: en

Keywords

automobile; cardiovascular implantable electronic device; electromagnetic interference; Keyless entry; pacemaker; radiofrequency