SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Heo JH, Yoon Y, Seo IS, Im SB, Ko YS, Lee S, Jang SJ. J. Forensic Leg. Med. 2023; 97: e102551.

Copyright

(Copyright © 2023, Elsevier Publishing)

DOI

10.1016/j.jflm.2023.102551

PMID

37339573

Abstract

PURPOSE: In cases of drowning, the presence of sphenoid sinus fluid is a non-specific autopsy finding. However, studies have reported that fluid accumulation in the paranasal sinuses is more commonly observed in drowning victims. Furthermore, some laboratory tests, such as diatom and electrolyte analysis, can serve as supplementary diagnostic tools for diagnosing drowning. Therefore, accurate sphenoid sinus fluid sampling is an important aspect of an autopsy in suspected drowning cases. The aim of this study was to identify the significance of evaluating sphenoid sinus fluid by PMCT images in cases of drowning.

METHODS: We retrospectively reviewed 54 drowning victims who underwent PMCT and forensic autopsy. Fluid volume in the sphenoid sinus was measured using a graduated syringe during autopsy and a three-dimensional (3D) workstation based on PMCT images was used for the purpose of comparison. The Mann-Whitney U test and Spearman's rank correlation coefficient was used to evaluate statistically significant differences and correlations. Additionally, a Bland-Altman plot was employed to assess the agreement between PMCT and autopsy.

RESULTS: The median volume was 1.65 (range 0.00-12.4) ml and 1.55 (range 0.00-7.00) ml in the PMCT and autopsy, respectively, showing a statistically insignificant difference (p = 0.294) and a significant correlation (Rs = 0.896). In 35 cases, the PMCT overestimated the fluid volume more than the autopsy, whereas in 14 cases, the PMCT underestimated the fluid volume. No fluid was identified in seven cases during the autopsy, whereas in five patients, no fluid was found in both PMCT and autopsy. By analyzing the Bland-Altman plot, a bias of 0.73 ± 1.4 ml and limits of agreement ranging from -2.04 to 3.51 ml were observed for sphenoid sinus fluid volume measurements.

CONCLUSIONS: Based on the limitations of traditional fluid volume measurement in the sphenoid sinus during autopsy, we propose the utilization of PMCT volumetric analysis prior to autopsy as a means to enhance the detection of sphenoid sinus fluid in cases of drowning.


Language: en

Keywords

Autopsy; Drowning; Forensic medicine; Fluid accumulations; Post-mortem computed tomography; Sphenoid sinus

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print