SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Phan VL, Yamamae Y, Tanaka H, Yasuki T. Trans. Soc. Automot. Eng. Jpn. 2021; 52(1): 184-189.

Copyright

(Copyright © 2021, Society of Automotive Engineers of Japan)

DOI

10.11351/jsaeronbun.52.184

PMID

unavailable

Abstract

As vehicle electrification progresses, physical spaces inside instrumental panel for a defroster nozzle become narrower and nozzle sizes are required to reduced. Under such constraint conditions, it is important to design a defroster nozzle, satisfying requirements of windshield defrosting-demisting performance with low costs. In this paper, a reduced order model (ROM) is developed to predict instantly windshield velocity distribution, namely windshield defrosting-demisting performance. An inverse design method utilizing decision tree algorithm and ROM is established to find out instantly design conditions of defroster nozzle that fulfill performance requirements. Effectiveness of the method is validated by CFD performance results of a small defroster nozzle derived from the method results.


Language: ja

Keywords

CFD; Defroster nozzle; Defrosting-demisting performance; Heat fluid; Inverse design; Reduced order model