윤. J. Korea Inst. Fire Sci. Eng. 2021; 35(1): 137-142.

Vernacular Title

방화문의 성능 관련 소송의 주요 쟁점에 관한 연구

Copyright

(Copyright © 2021, Korea Institute of Fire Science and Engineering)

DOI

10.7731/KIFSE.265d7867

PMID

unavailable

Abstract

In this study, we attempted to analyze the predominant issues that have emerged from the fire door litigation process that has been conducted until recently, and to suggest alternatives. The results of analyzing the contents and outcomes of fire door litigation were confirmed by the issue of the durability period of the fire doors' fire protection performance. Further, they were supported by the confirmation of the fire protection performance of fire doors that have already been installed, and the extent of the defect repair when the fire door performance is not confirmed. To solve these issues, performance verification must be executed at the manufacturing, delivery, and construction stages of fire doors. In the use stage, after completion, the user (Resident) should be the subject of performance maintenance. To this end, it is necessary to introduce the duty of maintenance and management of fire doors at the stage of use and the introduction of a professional inspection system that carries out inspections. Additionally, since the soundness of the fire door frame was confirmed through simulation and test results, the fire protection performance of the fire door in use can be confirmed by only separating the door. This can be achieved by excluding the door frame and conducting a test. It is considered that performance can be sufficiently secured despite the performance of the fire door being confirmed to be inferior, even if performance is improved by limiting the repair range to fire door pairs.

===

본 연구에서는 최근까지 계속되고 있는 방화문 소송과정에서 나타나는 주요 쟁점들을 분석하고, 이에 따른 대안을 제시하고자 하였다. 방화문 소송내용 및 결과를 분석하여 도출한 주요 쟁점은 방화성능의 내구연한, 기 설치된 방화문의 방화성능 확인절차, 그리고 방화문의 성능미달에 따른 하자보수의 범위 등으로 파악되었다. 이러한 문제 해결을 위해서 방화문의 제조, 납품, 시공단계에서 성능확인이 이루어져야 하며, 완공 이후 사용단계에서는 사용자(입주자)가 성능유지의 주체가 되도록 해야 한다. 이를 위해서 사용단계에서 방화문의 유지관리 의무 부여와 방화문 점검을 수행하는 전문 점검제도의 도입이 필요하다. 또한, 방화문틀의 건전성을 시뮬레이션 및 시험결과 등으로 분석한 바, 기 사용중인 방화문의 방화성능 확인은 문틀을 제외한 문짝만 성능시험을 실시해도 확인 가능할 것으로 판단되며, 성능미달이 확인된 경우에도 하자보수 범위를 방화문짝으로 한정하는 것이 바람직하다.


Language: ko

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print