Zheng Y, Zhang Z, Yan K, Guo H, Li M, Lian M, Liu Z. BMC Pediatr. 2021; 21(1): e179.

Copyright

(Copyright © 2021, Holtzbrinck Springer Nature Publishing Group - BMC)

DOI

10.1186/s12887-021-02642-y

PMID

unavailable

Abstract

BACKGROUND: The aim of this study was to characterize patients who ingested multiple rare-earth magnets, reveal the harm of rare-earth magnet foreign bodies in the digestive tract, and develop a clinical management algorithm.

METHODS: This was a retrospective review of patients with rare-earth magnet foreign bodies in the digestive tract admitted to a university-affiliated pediatric medical center in China, between January 2016 and December 2019; the subset of medical data evaluated included clinical symptoms, signs, treatments and outcomes.

RESULTS: A total of 51 cases were included in this study, including 36(70.6%) males and 15(29.4%) females. The magnets were passed naturally in 24(47.1%) patients and removed by intervention in 27(52.9%) patients, including 5(9.8%) cases by endoscopy and 22(43.1%) cases by surgery. Twenty-two (43.1%)cases had gastrointestinal obstruction, perforation, and fistula. Compared with the non-surgical group, the time of the surgical group from ingestion to arriving at the hospital was longer([80(5-336) vs 26(2-216)]hours, p < 0.001) while there was no significant difference in the mean age or the number of magnets swallowed.

CONCLUSIONS: Magnets are attractive to children, but lead to catastrophic consequences including gastrointestinal obstruction, perforation, and surgical interventions when ingested multiple magnets. Endoscopic resection should be urgently performed in the presence of multiple magnets as early as possible within 24 h, even in asymptomatic patients.

Keywords: Multiple magnet ingestion


Language: en

Keywords

Children; Foreign body; Multiple magnets ingestion; Perforation