Gutta V, Fallavollita P, Baddour N, Lemaire ED. IEEE J. Transl. Eng. Health Med. 2021; 9: e2100412.

Copyright

(Copyright © 2021, Institute of Electrical and Electronics Engineers)

DOI

10.1109/JTEHM.2021.3069353

PMID

33824790

Abstract

OBJECTIVE: In this research, a marker-less 'smart hallway' is proposed where stride parameters are computed as a person walks through an institutional hallway. Stride analysis is a viable tool for identifying mobility changes, classifying abnormal gait, estimating fall risk, monitoring progression of rehabilitation programs, and indicating progression of nervous system related disorders.

METHODS: Smart hallway was build using multiple Intel RealSense D415 depth cameras. A novel algorithm was developed to track a human foot using combined point cloud data obtained from the smart hallway. A method was implemented to separate the left and right leg point cloud data, then find the average foot dimensions. Foot tracking was achieved by fitting a box with average foot dimensions to the foot, with the box's base on the foot's bottom plane. A smart hallway with this novel foot tracking algorithm was tested with 22 able-bodied volunteers by comparing marker-less system stride parameters with Vicon motion analysis output.

RESULTS: With smart hallway frame rate at approximately 60fps, temporal stride parameter absolute mean differences were less than 30ms. Random noise around the foot's point cloud was observed, especially during foot strike phases. This caused errors in medial-lateral axis dependent parameters such as step width and foot angle. Anterior-posterior dependent (stride length, step length) absolute mean differences were less than 25mm.

CONCLUSION: This novel marker-less smart hallway approach delivered promising results for stride analysis with small errors for temporal stride parameters, anterior-posterior stride parameters, and reasonable errors for medial-lateral spatial parameters.


Language: en

Keywords

Foot tracking; Intel RealSense D415; marker-less; smart hallway; stride analysis