SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Klu JK, Officer JA, Park A, Mudie R, NicDaeid N. Forensic Sci. Int. 2021; 322: e110744.

Copyright

(Copyright © 2021, Elsevier Publishing)

DOI

10.1016/j.forsciint.2021.110744

PMID

unavailable

Abstract

A method for the quantitative analysis of delta-9-tetrahydrocannabinol (THC, the main active ingredient of cannabis) in whole blood using solid phase extraction and LC/MS/MS has been developed. A bottom-up approach with method validation data was used to evaluate and estimate the measurement uncertainty (MU) of the analytical method. The sources of uncertainty were identified using a cause and effect diagram. The contribution of each uncertainty component was estimated and were combined to derive the overall uncertainty of the analytical method. The combined uncertainty was estimated to be 0.131 μg/L (<7%). At a 99.7% confidence level, the expanded uncertainty was 0.393 μg/L for a THC concentration of 2 μg/L in a whole blood sample. The calculations not only enable the laboratory to quantify the uncertainty associated with a quantitative result, but can also be used to identify the sources of uncertainty and determine if the analytical method can be improved.


Language: en

Keywords

Bottom-up approach; Calibration curve; Measurement uncertainty; Method validation; THC, LC/MS/MS

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print