SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Czerniak LL, Liebel SW, Garcia GGP, Lavieri MS, McCrea MA, McAllister TW, Broglio SP, CARE Consortium Investigators. Sports Med. 2020; ePub(ePub): ePub.

Copyright

(Copyright © 2020, Adis International)

DOI

10.1007/s40279-020-01393-7

PMID

33315231

Abstract

BACKGROUND: To optimally care for concussed individuals, a multi-dimensional approach is critical and a key component of this assessment in the athletic environment is computer-based neurocognitive testing. However, there continues to be concerns about the reliability and validity of these testing tools. The purpose of this study was to determine the sensitivity and specificity of three common computer-based neurocognitive tests (Immediate Post-Concussion Assessment and Cognitive Testing [ImPACT], CNS Vital Signs, and CogState Computerized Assessment Tool [CCAT]), to provide guidance on their clinical utility.

METHODS: This study analyzed assessments from a cohort of collegiate athletes and non-varsity cadets from the NCAA-DoD CARE Consortium. The data were collected from 2014-2018. Study participants were divided into two testing groups [concussed, n = 1414 (baseline/24-48 h) and healthy, n = 8305 (baseline/baseline)]. For each test type, change scores were calculated for the components of interest. Then, the Normative Change method, which used normative data published in a similar cohort, and the Reliable Change Index (RCI) method were used to determine if the change scores were significant.

RESULTS: Using the Normative Change method, ImPACT performed best with an 87.5%-confidence interval and 1 number of components failed (NCF; sensitivity = 0.583, specificity = 0.625, F1 = 0.308). CNS Vital Signs performed best with a 90%-confidence interval and 1 NCF (sensitivity = 0.587, specificity = 0.532, F1 = 0.314). CCAT performed best when using a 75%-confidence interval and 2 NCF (sensitivity = 0.513, specificity = 0.715, F1 = 0.290). When using the RCI method, ImPACT performed best with an 87.5%-confidence interval and 1 NCF (sensitivity = 0.626, specificity = 0.559, F1 = 0.297).

CONCLUSION: When considering all three computer-based neurocognitive tests, the overall low sensitivity and specificity results provide additional evidence for the use of a multi-dimensional assessment for concussion diagnosis, including symptom evaluation, postural control assessment, neuropsychological status, and other functional assessments.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print