Carmichael H, Samuels JM, Wikiel KJ, Robinson TN, Barnett CC, Jones TS, Jones EL. Surg. Laparosc. Endosc. Percutan. Tech. 2019; ePub(ePub): ePub.

Affiliation

Department of Surgery, Rocky Mountain Regional Veterans Affairs Medical Center, Aurora, CO.

Copyright

(Copyright © 2019, Lippincott Williams and Wilkins)

DOI

10.1097/SLE.0000000000000734

PMID

31633578

Abstract

Surgical smoke evacuators may reduce the concentration of alcohol vapors from skin preparations at the site of electrosurgical device activation, decreasing operating room fire risk. Our aim was to compare the incidence of flames with and without smoke evacuation in a porcine ex vivo model. A monopolar device was activated after application of either 70% isopropyl alcohol/2% chlorhexidine gluconate (CHG-IPA) or 74% isopropyl alcohol/0.7% iodine povacrylex (iodine-IPA) skin preparations. No suction was compared with standard wall suction and 2 monopolar devices with built-in smoke evacuators. Flames were generated in 60% of CHG-IPA and 47% of iodine-IPA tests without suction. Wall suction did not significantly reduce fires (CHG-IPA 43% vs. 60%, P=0.30; iodine-IPA 57% vs. 47%, P=0.61). Use of both smoke evacuation devices reduced fires for CHG-IPA (17% vs. 60%, P=0.001 and 20% vs. 60%, P=0.004) but not for iodine-IPA. Smoke evacuation devices reduce fire risk when used with a chlorhexidine-alcohol skin preparation.