SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Kamel Gharghan S, Saad Fakhrulddin S, Al-Naji A, Chahl J. Sensors (Basel) 2019; 19(20): s19204452.

Affiliation

Joint and Operations Analysis Division, Defence Science and Technology Group, Melbourne, VIC 3207, Australia. Javaan.Chahl@unisa.edu.au.

Copyright

(Copyright © 2019, MDPI: Multidisciplinary Digital Publishing Institute)

DOI

10.3390/s19204452

PMID

31615095

Abstract

Elderly fall detection systems based on wireless body area sensor networks (WBSNs) have increased significantly in medical contexts. The power consumption of such systems is a critical issue influencing the overall practicality of the WBSN. Reducing the power consumption of these networks while maintaining acceptable performance poses a challenge. Several power reduction techniques can be employed to tackle this issue. A human vital signs monitoring system (HVSMS) has been proposed here to measure vital parameters of the elderly, including heart rate and fall detection based on heartbeat and accelerometer sensors, respectively. In addition, the location of elderly people can be determined based on Global Positioning System (GPS) and transmitted with their vital parameters to emergency medical centers (EMCs) via the Global System for Mobile Communications (GSM) network. In this paper, the power consumption of the proposed HVSMS was minimized by merging a data-event (DE) algorithm and an energy-harvesting-technique-based wireless power transfer (WPT). The DE algorithm improved HVSMS power consumption, utilizing the duty cycle of the sleep/wake mode. The WPT successfully charged the HVSMS battery. The results demonstrated that the proposed DE algorithm reduced the current consumption of the HVSMS to 9.35 mA compared to traditional operation at 85.85 mA. Thus, an 89% power saving was achieved based on the DE algorithm and the battery life was extended to 30 days instead of 3 days (traditional operation). In addition, the WPT was able to charge the HVSMS batteries once every 30 days for 10 h, thus eliminating existing restrictions involving the use of wire charging methods. The results indicate that the HVSMS current consumption outperformed existing solutions from previous studies.


Language: en

Keywords

GPS; GSM; WPT; accelerometer; battery life; data-event algorithm; fall detection; heartbeat; power saving

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print