Wong MF, Matić Z, Campiglia GC, Zimring CM, Mumma JM, Kraft CS, Casanova LM, Durso FT, Walsh VL, Shah PY, Shane AL, Jacob JT, Dubose JR. Clin. Infect. Dis. 2019; 69(Suppl 3): S241-S247.

Affiliation

SimTigrate Design Lab, Georgia State University, and College of Design.

Copyright

(Copyright © 2019, University of Chicago Press)

DOI

10.1093/cid/ciz617

PMID

31517982

Abstract

BACKGROUND: Few data exist to guide the physical design of biocontainment units, particularly the doffing area. This can impact the contamination risk of healthcare workers (HCWs) during doffing of personal protective equipment (PPE).

METHODS: In phase I of our study, we analyzed simulations of a standard patient care task with 56 trained HCWs focusing on doffing of high-level PPE. In phase II, using a rapid cycle improvement approach, we tested different balance aids and redesigned doffing area layouts with 38 students. In phase III, we tested 1 redesigned layout with an additional 10 trained HCWs. We assessed the effectiveness of design changes on improving the HCW performance (measured by occurrence and number of risky behaviors) and reducing the physical and cognitive load by comparing the results from phase I and phase III.

RESULTS: The physical load was highest when participants were removing their shoe covers without any balance aid; the use of a chair required the lowest physical effort, followed by horizontal and vertical grab bars. In the revised design (phase III), the overall performance of participants improved. There was a significant decrease in the number of HCW risky behaviors (P =.004); 5 risky behaviors were eliminated and 2 others increased. There was a significant decrease in physical load when removing disposable shoe covers (P =.04), and participants reported a similar workload in the redesigned doffing layout (P =.43).

CONCLUSIONS: Through optimizing the design and layout of the doffing space, we reduced risky behaviors of HCWs during doffing of high-level PPE.

© The Author(s) 2019. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.


Language: en

Keywords

Ebola; biocontainment unit design; design improvements; doffing personal protective equipment; occupational health