Khattak MA, Mukhtar A, Ghumman ISS, Jan MM. J. Fail. Anal. Prev. 2018; 18(2): 274-279.

Copyright

(Copyright © 2018, ASM International, Publisher Holtzbrinck Springer Nature Publishing Group)

DOI

10.1007/s11668-018-0412-x

PMID

unavailable

Abstract

Pressure cooker is a closed domestic pressure cooking vessel for use with external heat source and capable of maintaining nominal cooking pressure up to 1.0 kgf/cm2 (100 kN/m2 approximately) gauge nominal. In pressure cookers, despite the development of electronic controllers, the basic edition of such vessels are still equipped with fewer advanced safety functions due to economic constraints. Although the provision of pressure relief valves (PRV) is considered as one of the major protective features, however, pressure cooker failure accidents have been reported frequently. This paper describes the analysis of pressure cooker failure that failed prematurely after 1 year of service considering the design life of > 5 years. It was hypothesized that the root cause of pipe failure was either material degradation from exposure to an aggressive environment or an inherent defect in the pressure cooker. To test this hypothesis, a thorough visual examination of the exhumed failed section and the fracture surface was undertaken, followed by liquid penetrant testing, material identification, hardness testing, and metallographic analysis. Computational models of static and transient loading were also used to determine the stress distribution along the actual geometry of the failed cooker and to understand the main causes of recurrent failures. Visual and macroscale examination revealed significant body deformation at the lower dish-ended shell showing distorted locking grooves. It was also noticed that dirt and food particle, from the earlier cooking, were stuck in the pressure valves orifice. In addition, no evidence of metallurgical defect was observed. The inspection indicated that the cause of failure is primarily due to the choking of pressure relief value (PRV) and overpressure safety valves. Consequently, the pressure release occurred from the sealing side of the top lid, which resulted in its ejection.


Language: en

Keywords

Computational simulation; Failure analysis; NDT (nondestructive techniques); Pressure cooker; PRV chocking

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print