SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Umasabor RI, Okovido JO. Heliyon 2018; 4(12): e01035.

Affiliation

Civil Engineering Department, University of Benin, Nigeria.

Copyright

(Copyright © 2018, Elsevier Publishing)

DOI

10.1016/j.heliyon.2018.e01035

PMID

30582051

PMCID

PMC6299146

Abstract

This paper studied the fire resistance of rice husk ash concrete. An experimental method was adopted as the research design in this work, which produced one hundred and eighty four (184) concrete specimens with the addition of rice husk ash in weighted percentages of 5%, 10% and 15% respectively. They were cured and tested at 7 days, 28 days, 30 days, 60 days, 90 days, 120 days, 150 days and 200 days. After the targeted curing days, the specimen were exposed to temperatures of 100 °C, 200 °C, 300 °C, 400 °C, 500 °C, 600 °C and 700 °C for 2 hours in a muffle electric furnace. The results show that the pozzolanic concrete and control concrete fire resistance ranged between (60%-96%) for (200 °C-400 °C), (41%-55%) at 500 °C, and (13%-26%) for (600 °C-700 °C). It is concluded that 5% weighted RHA concrete performs better in fire than others.


Language: en

Keywords

Civil Engineering

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print