SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Lee C, Yang H. Nat. Hazards 2018; 92(1): 511-523.

Copyright

(Copyright © 2018, Holtzbrinck Springer Nature Publishing Group)

DOI

10.1007/s11069-018-3224-0

PMID

unavailable

Abstract

This paper describes a fire monitoring system, based on a thermographic camera, for electrical appliances in interior spaces. These appliances are at particular risk because they are vulnerable to the carelessness of users (46% of electrical appliances fires are caused this way). The system compromises a thermographic camera, rotating on a two-axis robotic arm, controlled by a fire monitoring algorithm that detects the appliances' status. Once the system's accuracy and ability to identify the status of each appliance had been tested, the camera's rotation sequence was planned. To achieve the best efficiency, bearing in mind that fires can break out very quickly, the sequence was based on the distance between monitored appliances. Over a nine-hour period, monitoring six appliances, the proposed method resulted in about 295 (about 7%) more rotations than those produced by a method of arbitrary ordering. This effectiveness increases when more appliances are monitored over greater periods. The system's main contribution to fire safety is the application and full utilization of the thermal camera, detecting the beginnings of a fire before it can break out.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print