SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Wiedfeld C, Krueger J, Skopp G, Musshoff F. Int. J. Legal Med. 2019; 133(1): 109-116.

Affiliation

Forensisch Toxikologisches Centrum GmbH, Bayerstraße 53, 80335, Munich, Germany.

Copyright

(Copyright © 2019, Holtzbrinck Springer Nature Publishing Group)

DOI

10.1007/s00414-018-1797-5

PMID

29453495

Abstract

Fluoride is a common stabilizing agent in forensic toxicology to avoid the frequent problem of degradation of drugs in blood samples especially described for cocaine. In cases only samples with addition of fluoride are available, it is a crucial question if also concentrations of common drugs other than cocaine (amphetamines, opiates and cannabinoids) are affected by fluoride. So far, there are only rare literature data available on discrepant results especially for Δ9-tetrahydrocannabinol (THC). In this study, comparative analysis of positive tested paired routine plasma/serum samples (n = 375), collected at the same time point (one device with and one without fluoride), was carried out with special focus on cannabinoids. Samples were measured with validated routine liquid chromatography-tandem mass spectrometry methods for THC, 11-hydroxy-THC (THC-OH), 11-nor-9-carboxy-THC (THC-COOH), cocaine, benzoylecgonine, ecgonine methyl ester, morphine, codeine, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxyethylamphetamine, and results were statistically evaluated. Beside the expected stabilization effect on cocaine and the consequently reduced concentration of ecgonine methyl ester in fluoride samples, benzoylecgonine was elevated compared to respective samples without fluoride. Most importantly, new findings were significantly reduced mean concentrations of THC (− 17%), THC-OH (− 17%), and THC-COOH (− 22%) in fluoride samples. Mean amphetamine concentration was significantly higher in samples with the additive (+ 6%). For the other amphetamine type of drugs as well as for morphine and codeine, no significant differences could be seen. Whenever specified thresholds have been set, such as in most European countries, the use of different blood sample systems may result in a motorist being differently charged or prosecuted. The findings will support forensic toxicologists at the interpretation of results derived from fluoride-stabilized blood samples.


Language: en

Keywords

Comparison; Drugs; Fluoride; Forensic toxicology; Limit values

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print