Funayama K, Fujihara J, Takeshita H, Takatsuka H. Leg. Med. (Elsevier) 2016; 23: 95-98.

Affiliation

Division of Legal Medicine, Department of Community Preventive Medicine, Niigata University Graduate School of Medicine and Dental Sciences, Niigata 951-8510, Japan. Electronic address: hisakazu@med.niigata-u.ac.jp.

Copyright

(Copyright © 2016, Japanese Society of Legal Medicine, Publisher Elsevier Publishing)

DOI

10.1016/j.legalmed.2016.10.006

PMID

27890112

Abstract

A foreign body impacted in the esophagus is not a rare incident among adults or children. In adults, a dental prosthesis is prone to become impacted in the esophagus. The diagnostic difficulty of this often causes a delay in its removal, which can lead to serious complications, including death. This report describes the autopsy case of a man who died of prolonged asphyxiation induced by the delayed removal of an impacted denture, which was misdiagnosed on his first visit notwithstanding that a part of the denture could be seen on X-rays. Cases in which an impacted denture led to death have rarely been reported in contrast to numerous papers about recovered cases.

Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.