SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Benayoun MD, Allen JW, Lovasik BP, Uriell ML, Spandorfer RM, Holder CA. J. Trauma Acute Care Surg. 2016; 81(2): 339-344.

Affiliation

From the Departments of Radiology and Imaging Sciences (M.D.B., J.W.A., M.U., C.A.H.), and Neurology (J.W.A.), School of Medicine (M.D.B., J.W.A., B.P.L., M.U., R.M.S., C.A.H.), Emory University, Atlanta, Georgia.

Copyright

(Copyright © 2016, Lippincott Williams and Wilkins)

DOI

10.1097/TA.0000000000001073

PMID

27454805

Abstract

BACKGROUND: Computed tomography (CT) of the cervical spine (C-spine) is routinely ordered for low-risk mechanisms of injury, including ground-level fall. Two commonly used clinical decision rules (CDRs) to guide C-spine imaging in trauma are the National Emergency X-Radiography Utilization Study (NEXUS) and the Canadian Cervical Spine Rule for Radiography (CCR).

METHODS: Retrospective cross-sectional study of 3,753 consecutive adult patients presenting to an urban Level I emergency department who received C-spine CT scans were obtained over a 6-month period. The primary outcome of interest was prevalence of C-spine fracture. Secondary outcomes included fracture stability, appropriateness of imaging by NEXUS and CCR criteria, and estimated radiation dose exposure and costs associated with C-spine imaging studies.

RESULTS: Of the 760 patients meeting inclusion criteria, 7 C-spine fractures were identified (0.92% ± 0.68%). All fractures were identified by NEXUS and CCR criteria with 100% sensitivity. Of all these imaging studies performed, only 69% met NEXUS indications for imaging (50% met CCR indications). C-spine CT scans in patients not meeting CDR indications were associated with costs of $15,500 to $22,000 by NEXUS ($14,600-$25,600 by CCR) in this single center during the 6-month study period.

CONCLUSION: For ground-level fall, C-spine CT is overused. The consistent application of CDR criteria would reduce annual nationwide imaging costs in the United States by $6.8 to $9.6 million based on NEXUS ($6.4-$15.6 million based on CCR) and would reduce population radiation dose exposure by 0.8 to 1.1 million mGy based on NEXUS (0.7-1.9 million mGy based on CCR) if applied across all Level I trauma centers. Greater use of evidence-based CDRs plays an important role in facilitating emergency department patient management and reducing systemwide radiation dose exposure and imaging expenditures. LEVEL OF EVIDENCE: Diagnostic study, level III.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print