Journal Article

Citation

Singh M, Nuutila K, Minasian R, Kruse C, Eriksson E. Burns 2016; 42(7): 1507-1512.

Affiliation

Division of Plastic Surgery, Department of Surgery, Brigham & Women's Hospital, Harvard Medical School, Boston MA 02115, United States. Electronic address: eeriksson@partners.org.

Copyright

(Copyright © 2016, Elsevier Publishing)

DOI

10.1016/j.burns.2016.02.019

PMID

27450518

Abstract

BACKGROUND: Porcine wounds closely mimic human wounds and are often used experimentally in burn studies. Multiple burn devices have been reported but they rarely described precise amount of heat transfer and the burn devices generally have low and varying heat capacity resulting in significant and varying temperature drop.

METHODS: The authors developed a customized aluminum burn device with cork insulation and high heat capacity. A thermistor probe was embedded in the device to accurately measure the temperature of the aluminum. The burn injury was inflicted by preheating the burn device to 100°C and pressing on the dorsum of pig skin for different time points ranging from 5 to 30s using standardized force of 10N on the device. With the knowledge of the heat capacity of the aluminum block and the temperature drop, the amount of heat transferred can be calculated.

RESULT: The temperature drop was 0°C, 1°C, 2°C, 3°C and 5°C for a wound-device contact time of 5, 10, 15, 20 and 30s, respectively. The depths of injury at 72h after burn were 0.46mm, 0.82mm, 1.21mm, 1.61mm and 1.91mm at 5, 10, 15, 20 and 30s respectively. 3.1mm represented a full thickness burn. The depth of the burn wounds significantly correlated with the heat transferred per cm(2) (correlation coefficient=0.96, p-value=0.03).

CONCLUSION: The authors describe a simple, standardized and reproducible animal burn model using a customized burn device. The high heat capacity ensures minimal temperature drop which minimizes the variability of heat transferred with a large temperature drop. The correlation between the heat transfer and the depth of injury can facilitate standardization of burn depths in future studies.

Copyright © 2016. Published by Elsevier Ltd.