SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Eden WJ, McRostie GC, Hall JS. Can. Geotech. J. 1973; 10(2): 180-192.

Copyright

(Copyright © 1973, National Research Council of Canada)

DOI

10.1139/t73-018

PMID

unavailable

Abstract

Contact pressures between supporting clay and the foundation raft of a very stiff, 15-storey building indicate that pressures near the edge of the raft were up to three times those near the center. This condition persisted over a 2-year period. The difference in pressure is discussed in the light of the stiffness of the building. The raft design method suggested by an A.C.I. Committee in 1966 is compared with the measured performance and found to be reasonable for the raft itself but questionable for the foundation wails above the raft.


Les contraintes au contact entre l'argile portante et le radier de fondation d'un édifice très rigide de 15 étages indiquent que les contraintes près du bord du radier sont jusqu'à trois fois plus grandes que près du centre. Cette condition a persisté pendant une période de 2 ans. L'auteur examine cette différence de contrainte à la lumière de la rigidité de l'édifice. En comparant avec le fonctionnement mesuré la méthode de conception suggérée en 1966 par un comité de l'American Concrete Institute, on constate que celle-ci est convenable pour le radier même mais douteuse pour les murs de fondation au-dessus du radier.