SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Waddell BS, Waddell WH, Godoy G, Zavatsky JM. Spine 2015; 41(4): E231-6.

Affiliation

*Hospital for Special Surgery, 535 East 70th St, New York, NY 10021 †LSU Medical School New Orleans, 533 Bolivar St, New Orleans, LA 70112 ‡Ochsner Medical Center, 1514 Jefferson Highway, New Orleans, LA 70121 §Scoliosis & Deformity Institute, Florida Orthopaedic Institute, 13020 Telecom Parkway North, Tampa, FL 33637.

Copyright

(Copyright © 2015, Lippincott Williams and Wilkins)

DOI

10.1097/BRS.0000000000001204

PMID

26571167

Abstract

STUDY DESIGN: Anthropomorphic phantoms were used to measure radiation exposure to the surgeon phantom's eye. Groups analyzed were: Group 1 - no glasses (None); Group 2 - leaded lenses without lead sides (WOLS); Group 3 - leaded lenses with lead sides (WLS); Group 4 - sport wraparound leaded glasses (Sport). Glasses were 0.75 mm lead equivalent OBJECTIVE.: Evaluate the efficacy of three types of leaded eyeglasses at reducing radiation exposure to the lens during typical views of minimally invasive spine surgery. SUMMARY OF BACKGROUND DATA: Minimally invasive spine surgery relies upon fluoroscopic x-ray. Ocular radiation exposure is associated with cataract formation. Leaded glasses can reduce ocular radiation exposure.

METHODS: Fifteen individual 20-second exposures with the fluoroscopic C-arm in the anteroposterior (AP) and lateral positions, with phantom head positioned at 0, 45, and 90 degrees to the fluoroscope were performed. Radiation was measured using a solid-state dosimeter. Student t-test was used to calculate significance.

RESULTS: All glasses (WOLS, WLS, Sport) had significant reductions in ocular radiation versus no glasses, at all individual head positions (p ≤ 1.31 × 10). Sport had significantly lower ocular radiation dose than WLS at all head positions except at 90 degrees AP (p = 0.001). WOLS had significantly lower ocular radiation dose than Sport in 3 out of 6 cases including phantom head at 0 degrees AP (p = 0.0003), 90 degrees AP (p = 4.46 × 10), and 90 degrees lateral (p = 7.38 × 10). WOLS had significantly lower radiation dosage at all head positions than WLS except at 45 degrees AP (p = 0.303). All glasses resulted in a significant reduction in total radiation dose from all head positions over no glasses (p ≤ 8.37 × 10).

CONCLUSIONS: We demonstrate a significant reduction in ocular radiation exposure with all three types of leaded glasses. Lead glasses without lead sides(WOLS) and the sport wraparound-type(Sport) were the most effective at reducing ocular radiation. LEVEL OF EVIDENCE: 3.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print