SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Ida T, Iwazaki H, Kawaguchi Y, Kawauchi S, Ohkura T, Iwaya K, Tsuda H, Saitoh D, Sato S, Iwai T. Wound Repair Regen. 2015; 24(2): 349-355.

Affiliation

New Concept Product Initiative, Advantest Corporation.

Copyright

(Copyright © 2015, Wiley-Blackwell)

DOI

10.1111/wrr.12374

PMID

26487320

Abstract

Diagnosis of burn depths is crucial to determine the treatment plan for severe burn patients. However, an objective method for burn depth assessment has yet to be established, although a commercial laser Doppler imaging (LDI) system is used limitedly. We previously proposed burn depth assessment based on photoacoustic imaging (PAI), in which thermoelastic waves originating from blood under the burned tissue are detected, and we showed the validity of the method by experiments using rat models with three different burn depths: superficial dermal burn, deep dermal burn and deep burn. On the basis of those results, we recently developed a real-time PAI system for clinical burn diagnosis. Before starting a clinical trial, however, there is a need to reveal more detailed diagnostic characteristics, such as linearity and error, of the PAI system as well as to compare its characteristics with those of an LDI system. In this study, we prepared rat models with burns induced at six different temperatures from 70°C to 98°C, which showed a linear dependence of injury depth on the temperature. Using these models, we examined correlations of signals obtained by PAI and LDI with histologically determined injury depths and burn induction temperatures at 48 h postburn. We found that the burn depths indicated by PAI were highly correlative with histologically determined injury depths (depths of viable vessels) as well as with burn induction temperatures. Perfusion values measured by LDI were less correlative with these parameters, especially for burns induced at higher temperatures, being attributable to the limited detectable depth for light involving a Doppler shift in tissue. In addition, the measurement errors in PAI were smaller than those in LDI. On the basis of these results, we will be able to start clinical studies using the present PAI system. This article is protected by copyright. All rights reserved.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print