SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Rahman ZH, Leahy NE, Sessler K, Greenway A, Sorensen L, Breznak K, Rabbitts A, Macklay H, Yurt RW. J. Burn Care Res. 2015; 37(3): 160-165.

Affiliation

From the *Weill Cornell Medical College in Qatar, Doha, Qatar; †New York-Presbyterian/Weill Cornell Medical Center, New York, New York; and ‡Weill Cornell Medical College, New York, New York.

Copyright

(Copyright © 2015, American Burn Association, Publisher Lippincott Williams and Wilkins)

DOI

10.1097/BCR.0000000000000306

PMID

26317836

Abstract

The pediatric early warning score (PEWS) tool helps providers to detect subtle clinical deterioration in non-intensive care unit pediatric patients and intervene early to prevent significant adverse outcomes. Although widely used in general pediatrics, limited studies report on its validation; none report on use with burn-injured patients. This center modified a general PEWS system to a burn-specific PEWS and integrated its use into standard practice. This study investigated the external validity of the PEWS process in clinical practice. Fifty cases of patients aged 0 to 15.9 years admitted between January 2012 and June 2013, whose length of stay (LOS) more than 3 days were selected for review from this cohort of n equal to 187. Demographics, total PEWS and score changes, and compliance with PEWS documentation and with resultant interventions were reviewed. Continuous variables are presented as mean ± SD, P less than 0.05. Mean age, burn size, and LOS were 3.2 ± 3.3 years, 4.8 ± 5.7%, and 9.8 ± 7.0 days; 26% required grafting, and 50% were male. No mortalities occurred. One thousand six hundred and twelve PEWS from 1745 opportunities were documented (92.4%). For all PEWS (n = 1612) and PEWS greater than 0 (n = 912), means were 0.9 ± 1.2 and 1.6 ± 1.2, respectively. Among the 162 PEWS increase events, intake (54.1%) and output (4.5%) parameters increased most commonly. Of these, 129 PEWS increases (79.6%) were followed by an intervention that most commonly included text notation of score increase (93.7%), MD/physician assistant notification (70.5%), and feeding-tube insertion (25.6%). Patients with PEWS greater than 0 had similar age, LOS, and larger burn size (5.2% vs 1.4%, P < 0.05) than those with PEWS equal to 0. Compliance with PEWS performance and resultant actions based on score increases are high. Data support that even small changes in burn-injury specific PEWS stimulate provider discussion and intervention and support its validation; further studies on its effect on practice are warranted.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print