Liu DX, He JN. Fa Yi Xue Za Zhi 2014; 30(6): 452-455.

Copyright

(Copyright © 2014, Si fa bu Si fa jian ding ke xue ji shu yan jiu suo)

DOI

unavailable

PMID

25816578

Abstract

OBJECTIVE: To discuss blood collection tubes with different additives and their effects on the testing results of alcohol concentration in blood samples.

METHODS: Blood samples from 10 volunteers were collected 2 hours after drinking with seven different types of disposable vacuum blood collection tubes, including ordinary tube without anticoagulant, coagulant tube, separating gel-coagulant tube, sodium citrate (1:4) tube, sodium citrate (1:9) tube, sodium citrate (9:1) tube and EDTA-K2 tube. The alcohol concentrations in these blood samples were analyzed by headspace gas chromatography.

RESULTS: The concentration testing results of the same blood samples in different types of tubes were different from one to another. The sequence was as follows: separating gel-coagulant tube > coagulant tube > ordi- nary tube without anticoagulant > EDTA-K2 tube> sodium citrate (1:9) tube> sodium citrate (1:4) tube, whereas the results of the same blood sample in sodium citrate (1:9) tube and sodium citrate (9:1) tube showed no obvious difference.

CONCLUSION: It is better to collect a suspicious drunk driver's blood sam- ple using a disposable vacuum blood collection tube, with the EDTA-K2 tube being preferred.