SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Theusinger OM, Baulig W, Seifert B, Müller SM, Mariotti S, Spahn DR. Anesth. Analg. 2014; 120(3): 627-635.

Affiliation

From the *Institute of Anesthesiology, University and University Hospital Zurich, Zurich, Switzerland; †Division of Biostatistics, Institute of Social and Preventive Medicine, University of Zurich, Zurich, Switzerland; and ‡Schutz und Rettung Stadt Zürich, Zurich, Switzerland.

Copyright

(Copyright © 2014, International Anesthesia Research Society, Publisher Lippincott Williams and Wilkins)

DOI

10.1213/ANE.0000000000000561

PMID

25545751

Abstract

BACKGROUND:: When trauma patients arrive in the emergency department (ED), coagulopathy frequently is present. The time course, however, in which this coagulopathy develops is poorly understood. No study has fully evaluated the coagulation status, including thromboelastometry on-scene and at hospital arrival. We hypothesized that measured coagulation variables might change when measured at the scene of injury and upon arrival to the ED.

METHODS:: We performed a prospective, single-center, observational study investigating coagulation status in 50 trauma patients on-scene and at arrival in the ED. Measurements included arterial blood gases, ROTEM®, protein S100, protein C activity, protein S, Quick value, international normalized ratio, activated partial thromboplastin time, D-dimer, coagulation factor V (FV), coagulation factor XIII (FXIII), fibrinogen, hemoglobin, hematocrit, platelets, and volume and blood products being administered during the first 24 hours.

RESULTS:: Significant changes between on-scene and the ED were observed for the following values: partial venous oxygen pressure increased and sodium, glucose, and lactate decreased. For EXTEM, INTEM, and APTEM, clotting time and clot formation time increased significantly, whereas maximal clot firmness and angle α decreased significantly (all P ≤ 0.004). For FIBTEM, clotting time increased significantly and maximal clot firmness decreased significantly. In the laboratory, significant reductions in hemoglobin, hematocrit, platelets, activated partial thromboplastin time, fibrinogen, FV, FXIII, protein C activity, protein S, and protein S100 were observed (all P ≤ 0.001).

CONCLUSIONS:: Although most all laboratory and rotational thromboelastometry coagulation tests worsened over time when measured on-scene and in the ED, monitoring coagulation at the scene of trauma does not provide clinically important information in a majority of trauma patients. One hour after injury, significant activation and consumption of fibrinogen, FV, FXIII, protein C activity, and protein S were observed.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print