SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

van der Meulen O, Soetens F, Maljaars J. J. Struct. Fire Eng. 2014; 5(2): 161-174.

Copyright

(Copyright © 2014, Emerald Group Publishing)

DOI

10.1260/2040-2317.5.2.161

PMID

unavailable

Abstract

Fire is often the dominant design criterion for aluminium structures. Present design rules for aluminium constructions in fire neglect both the decrease in susceptibility to local buckling and the effects of creep, that are intrinsic to aluminium. They may therefore either overestimate or underestimate the temperature of failure, depending on the load and exposure period. As part of a larger research program aimed at remedying this situation, the present paper reports the results of an experimental study on 28 aluminium SHS members of alloy AA6060-T66 loaded in bending, with different cross-sections, temperatures, and rates of heating. The experimental set-up employs an electric heating tube or 'sock' on the inside of the specimen as well as heated supports and load application point, which give a high degree of control of temperature in time.


Language: en