SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Reischl U, Reischl P. Am. Ind. Hyg. Assoc. J. 1978; 39(7): 563-569.

Copyright

(Copyright © 1978, American Industrial Hygiene Association)

DOI

10.1080/0002889778507809

PMID

696611

Abstract

A standard one-piece firefighter proximity suit (jumpsuit style) was tested for heat accumulation and hood compartment ventilation. Large increases in temperature of the skin and hood compartmental air were recorded. Oxygen and carbon dioxide were monitored and hypoxic conditions found. Using the O2 and CO2 data, mathematical regression analyses were performed to predict the time exposures allowed for firemen entering various ambient atmospheric conditions. The short permissible exposure periods predicted for the proximity suit suggests limited usefulness and the need for immediate improvements in the design of the suit.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print