SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Wille SM, Di Fazio V, Ramírez-Fernández MM, Kummer N, Samyn N. Ther. Drug. Monit. 2013; 35(1): 101-111.

Affiliation

Laboratory of Toxicology, National Institute of Criminalistics and Criminology, Brussels, Belgium. sarah.wille@just.fgov.be

Copyright

(Copyright © 2013, Lippincott Williams and Wilkins)

DOI

10.1097/FTD.0b013e318278dbe4

PMID

23318281

Abstract

BACKGROUND: "Driving under the influence of drugs" (DUID) has a large impact on the worldwide mortality risk. Therefore, DUID legislations based on impairment or analytical limits are adopted. Drug detection in oral fluid is of interest due to the ease of sampling during roadside controls. The prevalence of Δ9-tetrahydrocannabinol (THC) in seriously injured drivers ranges from 0.5% to 7.6% in Europe. For these reasons, the quantification of THC in oral fluid collected with 3 alternative on-site collectors is presented and discussed in this publication. METHODS: An ultra-performance liquid chromatography-mass spectrometric quantification method for THC in oral fluid samples collected with the StatSure (Diagnostic Systems), Quantisal (Immunalysis), and Certus (Concateno) devices was validated according to the international guidelines. Small sample volumes of 100-200 μL were extracted using hexane. Special attention was paid to factors such as matrix effects, THC adsorption onto the collector, and stability in the collection fluid. RESULTS: A relatively high-throughput analysis was developed and validated according to ISO 17025 requirements. Although the effects of the matrix on the quantification could be minimized using a deuterated internal standard, and stability was acceptable according the validation data, adsorption of THC onto the collectors was a problem. For the StatSure device, THC was totally recovered from the collector pad after storage for 24 hours at room temperature or 7 days at 4°C. A loss of 15%-25% was observed for the Quantisal collector, whereas the recovery from the Certus device was irreproducible (relative standard deviation, 44%-85%) and low (29%-80%). During the roadside setting, a practical problem arose: small volumes of oral fluid (eg, 300 μL) were collected. However, THC was easily detected and concentrations ranged from 8 to 922 ng/mL in neat oral fluid. CONCLUSION: A relatively high-throughput analysis (40 samples in 4 hours) adapted for routine DUID analysis was developed and validated for THC quantification in oral fluid samples collected from drivers under the influence of cannabis.


Keyword: Cannabis impaired driving


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print