SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Putnam JB, Somers JT, Untaroiu CD. Traffic Injury Prev. 2014; 15(8): 844-854.

Affiliation

Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Virginia Tech , Blacksburg , VA , USA.

Copyright

(Copyright © 2014, Informa - Taylor and Francis Group)

DOI

10.1080/15389588.2014.880886

PMID

24433158

Abstract

Introduction/OBJECTIVE: In an effort to continually improve upon the design of the test device for human occupant restraint (THOR) dummy, a series of modifications have recently been applied. The first objective of this study was to update the THOR head-neck finite element (FE) model to the specifications of the latest dummy modifications. The second objective was to develop and apply a new optimization-based methodology to calibrate the FE head-neck model based on experimental test data. The calibrated head-neck model was validated against both frontal and lateral impact test data. Finally, the sensitivities of the model, in terms of head and neck injury criteria, to pre-test positioning conditions were evaluated in a frontal crash test simulation. METHODS: The updated parts of the head-neck THOR FE model were re-meshed from CAD geometries of the modified parts. In addition, further model modifications were made to improve the effectiveness of the model (e.g., model stability). A novel calibration methodology, which incorporates the CORA (CORelation and Analysis) rating system with an optimization algorithm implemented in Isight software, was developed to improve both kinematic and kinetic responses of the model in various THOR dummy certification and biomechanical response tests. A parametric study was performed to evaluate head and neck injury criteria values in the calibrated head-neck model, during a 40 km/h frontal crash test, with respect to variation in the THOR model upper body and belt pre-test position. RESULTS: Material parameter optimization was shown to greatly improve the updated model response by increasing the average rating score from 0.794 ± 0.073 to 0.964 ± 0.019. The calibrated neck showed the biggest improvement in the pendulum flexion simulation from 0.681 in the original model up to 0.96 in the calibrated model. The fully calibrated model proved to be effective at predicting dummy response in frontal and lateral loading conditions during the validation phase (0.942 average score). Upper body position was shown to have a greater effect on head-neck response than belt position. The pre-test positioning variation resulted in a 10% maximum change in HIC36 values and 14% maximum change in NIJ values. CONCLUSION: The optimization-based calibration methodology was effective as it markedly improved model performance. The calibrated head-neck model demonstrated application in a crash safety analysis, showing slight head-neck injury sensitivity to pre-test positioning in a frontal crash impact scenario.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print