Schoknecht G, Kophamel-Röder B, Fleck K. Blutalkohol 1991; 28(4): 210-223.

Vernacular Title

Vorschlag zur Realisierung einer beweissicheren Atemalkoholmessung.

Affiliation

Institut fur Sozialmedizin und Epidemiologie, Bundesgesundheitsamtes.

Copyright

(Copyright © 1991, International Committee on Alcohol, Drugs and Traffic Safety and Bund gegen Alkohol und Drogen im Straßenverkehr, Publisher Steintor Verlag)

DOI

unavailable

PMID

1910659

Abstract

Evidential breath-alcohol analysis requires measuring devices which cannot yet be obtained from industrial manufacturers. In order to avoid the influence of environment and breath techniques and to relate the breath-alcohol concentration to a standard temperature of 34 degrees C it is necessary to measure the breath temperature with a special device. The required reliability of measured results can only be obtained with two measuring systems operating independently from each other. When two measuring systems of different analytical specificity towards interfering substances are used, the infrared method allows a widely selective determination of ethanol. This is a prerequisite for the legal calibration of breath-alcohol analysers.