Hümpfner R, Hein PM. Blutalkohol 1992; 29(6): 365-371.

Vernacular Title

Untersuchungen zur Beeinflussbarkeit der Alcomat-Atemalkoholmessung durch Benzin.

Affiliation

Institut fur Rechtsmedizin, Universitat Wurzburg.

Copyright

(Copyright © 1992, International Committee on Alcohol, Drugs and Traffic Safety and Bund gegen Alkohol und Drogen im Straßenverkehr, Publisher Steintor Verlag)

DOI

unavailable

PMID

1476695

Abstract

We examined the period breath-alcohol values may be falsified owing to gasoline vapors with regard to the Alcomat currently used in routine tests. In a sober test person the breath-alcohol concentration was found to be 0.10/1000 24 min. after the inhalation of gasoline vapors, whereas the value measured after 28 min. was still 0.09/1000. 63 min. after the clothes had been moistened with gasoline, a breath-alcohol concentration of still 0.11/1000 could be identified immediately after inhalation.