Hansen R. Int. J. Wildland Fire 2012; 21(5): 525-536.

Copyright

(Copyright © 2012, International Association of Wildland Fire, Fire Research Institute, Publisher CSIRO Publishing)

DOI

10.1071/WF11022

PMID

unavailable

Abstract

In wildland fires where water is used as the primary extinguishing agent, one of the issues of wildfire suppression is estimating how much water is required to extinguish a certain section of the fire. In order to use easily distinguished and available indicators, the flame length and the area of the active combustion zone were chosen as suitable for the modelling of extinguishing requirements. Using Byram's and Thomas' equations, the heat release rate per unit length of fire front was calculated for low-intensity surface fires, fires with higher wind conditions, fires in steep terrain and high-intensity crown fires. Based on the heat release rate per unit length of fire front, the critical water flow rate was calculated for the various cases. Further, the required amount of water for a specific active combustion zone area was calculated for various fuel models. Finally, the results for low-intensity surface fires were validated against fire experiments. The calculated volumes of water can be used both during the preparatory planning for incidents as well as during firefighting operations.