SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Lampert R, Olshansky B, Heidbuchel H, Lawless C, Saarel E, Ackerman MJ, Calkins H, Estes NAM, Link MS, Maron BJ, Marcus F, Scheinman M, Wilkoff BL, Zipes DP, Berul CI, Cheng A, Law I, Loomis M, Barth C, Brandt C, Dziura JD, Li F, Cannom D. Circulation 2013; 127(20): 2021-2030.

Affiliation

Yale University School of Medicine, 789 Howard Ave, Dana 319, New Haven, CT 06511. rachel.lampert@yale.edu.

Copyright

(Copyright © 2013, American Heart Association, Publisher Lippincott Williams and Wilkins)

DOI

10.1161/CIRCULATIONAHA.112.000447

PMID

23690453

Abstract

BACKGROUND: The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. METHODS AND RESULTS: Athletes with ICDs (age, 10-60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21-46 months) follow-up, there were no occurrences of either primary end point-death or resuscitated arrest or arrhythmia- or shock-related injury-during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. CONCLUSIONS: Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print