SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Duncan J, Konz S. Proc. Hum. Factors Ergon. Soc. Annu. Meet. 1975; 19(3): 359-363.

Copyright

(Copyright © 1975, Human Factors and Ergonomics Society, Publisher SAGE Publishing)

DOI

10.1177/154193127501900316

PMID

unavailable

Abstract

A personal dry-ice cooling jacket for workers in industrial heat stress environments was developed following three stages of prototype design and evaluation. Model-B2 was evaluated in two laboratory heat stress environments (dry-bulb temperatures of 35 and 45 °C) on two male subjects pedalling 60 minutes. Garment variables were dry-ice surface area and pocket insulation.
Mean heart rate throughout the 60 minute exposure was 14 beats/min less with the jacket in the 45 °C environment and 18 beats/min less in the 35 °C environment. Mean rate of sweat loss was 0.06 kg/hr·m2 less with the jacket at 45 °C and 0.21 less at 35 °C. Mean rectal temperature was 0.61 °C less with the jacket at 45 °C and 0.49 °C less at 35 °C. Both the head and arm temperatures were significantly cooler while wearing the jacket. Oxygen uptake was 24% higher with the jacket, suggesting that heat production by non-shivering thermogenesis may occur when the jacket is worn. Dry-ice surface area affected skin and rectal temperatures.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print