Fan L, Wang E. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 2006; 23(6): 1245-1249.

Affiliation

Mechanical Engineering School, Nanjing University of Science and Technology, Nangjing 210094, China. fanlixia@yahoo.com

Copyright

(Copyright © 2006, Sichuan Sheng sheng wu yi xue gong cheng xue hui)

DOI

unavailable

PMID

17228718

Abstract

The effects of loading conditions on the structural capacity of the proximal femur were investigated parametrically by Finite Element Analysis (FEA) combined with Hoffman failure criterion. The loading conditions included the fall configuration angles, load locations and the friction resistance in hip joint. The results of this parametric study revealed that the load locations are the keys to determining the structural capacity of the proximal femur. There are two low peaks of the structural capacity when the loads are applied to femoral head. If the impact load were applied in this area, the fracture risk would be great. The frictional resistance of the hip joint can severely affect the failure load, which has far reaching implications in terms of osteoarthritis.