SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Valič B, Kos B, Gajšek P. Int. J. Occup. Safety Ergonomics 2012; 18(2): 161-170.

Affiliation

Institute of Non-Ionizing Radiation, Ljubljana, Slovenia. blaz.valic@inis.si.

Copyright

(Copyright © 2012, Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy, Publisher Informa - Taylor and Francis Group)

DOI

unavailable

PMID

22721535

Abstract

Occupational exposure caused by large broadcasting transmitters exceeds current reference levels. As it is common for different radio and TV transmitters to share the location, we analysed combined exposure on a 40-m high mast. The frequency modulation (FM) transmitter, located between the 10th and 30th metre, had the power of 25 kW, whereas an ultra-high frequency (UHF) transmitter of 5 kW occupied the top 8 m of the mast. Measured and calculated values of the electric field strength exceeded the reference levels up to 10 times; however, the results for the specific absorption rate (SAR) values show that the reference levels are very conservative for FM exposure, i.e., basic restrictions are not exceeded even when the reference levels are exceeded 10 times. However, for UHF exposure the reference levels are not conservative; they give a good prediction of real exposure.