SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Irle H, Hesse JM, Strasser H. Int. J. Ind. Ergonomics 1998; 21(6): 451-463.

Copyright

(Copyright © 1998, Elsevier Publishing)

DOI

unavailable

PMID

unavailable

Abstract

In industry continuous or impulse noise does not occur exclusively; rather it is a combination of both. If low-level continuous noise or impulse noise (below 120 dB) is added to an already existing high-level continuous noise this often numerically causes no essential increase in the rating level. Yet, it cannot be expected that also aural strain of these exposures is always negligible. Therefore, in a cross-over test series, ten male subjects (Ss) were exposed to white noise of 94 dB(A) for 1 h (TS I), energy-equivalent to an 8 h-rating level LArd of 85 dB(A). In a second test series (TS II) the same exposure was combined with 900 energetically negligible 5-ms impulses with a noise level of 113 dB(A) which increased the rating level by only 0.4 dB. The noise exposure of TS I and TS II was followed by an idealized resting phase in a soundproof cabin. In a third test series (TS III) the continuous noise of 94 dB(A) / 1 h was followed by 3 h of white noise at 70 dB(A). Such an additional load increases the LArd by merely 0.1 dB to 85.1 dB(A). In all three test series, the noise-induced temporary threshold shift (TTS2) and its restitution were measured. The continuous noise exposure of 94 dB(A) for 1 h was associated with a TTS2 of around 20 dB which disappeared completely after about 2 h. The additional impulse noise caused a small increase in the TTS2 and a prolongation of the restitution time. The maximum mean temporary threshold shift for the group increased only slightly (from 22.5 to 25.9 dB, which nevertheless can be statistically proven at a significance level of p [ges]0.99). Yet, more importantly, the restitution time increased from 126 to 175 min, i. e. 3 h, which can be statistically proven at a significance level of p[ges]0.95. The TTS2-values of TS III did not differ significantly from those resulting from TS I. That was expected as the conditions up to that point in time were identical. But due to the additional subsequent exposure, the mean restitution time increased considerably from 126 min up to 240 min (4 h). The mean total physiological cost represented by the integrated restitution temporary threshold shift (IRTTS) increased in TS II by approximately 40% and in TS III even by 140%.Relevance to industryThe results of the study show that levels of noise which have no influence on the rating level which traditionally is calculated according to the energy-equivalence principle are often of great importance, as they can lead to considerably prolonged restitution times. Therefore, the purely energy-equivalent determination of the rating level of both impulse noise and low sound levels can lead to an underestimation of latent problems so that over time a reversible TTS can evolve into a permanent threshold shift. The results are also of importance for the acoustic design of break rooms for noise-exposed workers. There should be conditions that allow an undisturbed restitution of hearing.

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print