SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Dubowski KM. J. Anal. Toxicol. 1994; 18(6): 306-311.

Affiliation

University of Oklahoma Health Sciences Center, Department of Medicine, Oklahoma City.

Copyright

(Copyright © 1994, Preston Publications)

DOI

unavailable

PMID

7823537

Abstract

Evidential breath-alcohol testing requires an adequate quality assurance (QA) program to safeguard the testing process and validate its results. A comprehensive QA program covers (a) test subject preparation and participation; (b) the analysis process; (c) test result reporting and records; (d) proficiency testing, inspections, and evaluations; and (e) facilities and personnel aspects. Particularly important are the following necessary scientific safeguards as components of quality control: (a) a pretest deprivation-observation period of at least 15 minutes; (b) blank tests immediately preceding each breath-collection step; (c) analysis of at least duplicate breath specimens; and (d) a control test accompanying every subject test. These safeguards have withstood adversarial challenges in the judicial system for more than 30 years.