SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Dzwiarek M. Int. J. Occup. Safety Ergonomics 1998; 4(3): 363-384.

Affiliation

Central Institute for Labour Protection, Poland. madzw@ciop.pl

Copyright

(Copyright © 1998, Centralny Instytut Ochrony Pracy - PaƄstwowy Instytut Badawczy, Publisher Informa - Taylor and Francis Group)

DOI

unavailable

PMID

10602628

Abstract

The Double Penetration Method (DPM) method of measuring ESPD (Electrosensitive Protective Device) response time was presented by D wiarek (1997). Calibrating the measuring equipment is a crucial stage of the procedure. Experimental verification of theoretical predictions is also crucial. For calibration purposes, a device simulating real ESPD operation thus enabling a correct setting of the response time was designed (Dzwiarek, 1997). Theoretical analysis has shown that measuring ESPD response time with the DPM is subject to localisation errors made in the localisation of the detection zone border, rod position measurement errors made during high-speed penetration, and time delay measurement errors. The values of all those components of the total error have been determined experimentally using the calibrating device. Measurements have been taken under conditions as close to real ones as possible proving that the total measurement error is really enclosed within the assumed limits.