SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Patel AB, Waters NM, Ghali WA. Int. J. Health Geogr. 2007; 6: 47.

Affiliation

Department of Geography, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada. alpatel@ucalgary.ca

Copyright

(Copyright © 2007, Holtzbrinck Springer Nature Publishing Group - BMC)

DOI

10.1186/1476-072X-6-47

PMID

17939870

PMCID

PMC2173884

Abstract

BACKGROUND: This study uses geographic information systems (GIS) as a tool to evaluate and visualize the general accessibility of areas within the province of Alberta (Canada) to cardiac catheterization facilities. Current American and European guidelines suggest performing catheterization within 90 minutes of the first medical contact. For this reason, this study evaluates the populated places that are within a 90 minute transfer time to a city with a catheterization facility. The three modes of transport considered in this study are ground ambulance, rotary wing air ambulance and fixed wing air ambulance. METHODS: Reference data from the Alberta Chart of Call were interpolated into continuous travel time surfaces. These continuous surfaces allowed for the delineation of isochrones: lines that connect areas of equal time. Using Dissemination Area (DA) centroids to represent the adult population, the population numbers were extracted from the isochrones using Statistics Canada census data. RESULTS: By extracting the adult population from within isochrones for each emergency transport mode analyzed, it was found that roughly 70% of the adult population of Alberta had access within 90 minutes to catheterization facilities by ground, roughly 66% of the adult population had access by rotary wing air ambulance and that no population had access within 90 minutes using the fixed wing air ambulance. An overall understanding of the nature of air vs. ground emergency travel was also uncovered; zones were revealed where the use of one mode would be faster than the others for reaching a facility. CONCLUSION: Catheter intervention for acute myocardial infarction is a time sensitive procedure. This study revealed that although a relatively small area of the province had access within the 90 minute time constraint, this area represented a large proportion of the population. Within Alberta, fixed wing air ambulance is not an effective means of transporting patients to a catheterization facility within the 90 minute time frame, though it becomes advantageous as a means of transportation for larger distances when there is less urgency.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print