Deaton TG, Roby JL. J. Spec. Oper. Med. 2010; 10(2): 22-25.

Copyright

(Copyright © 2010, Breakaway Media)

DOI

unavailable

PMID

20936600

Abstract

Purpose: The purpose of this investigation was to determine the injury profile of the steerable, SF-10A, static-line parachute. Methods: The investigation evaluated prospectively 972 low-level static-line training jumps for major injuries that required CASEVAC from the drop zone and for minor injuries that allowed the jumpers to continue with their training mission. Results: The investigation found overall injury rates to be 8.23 per 1000 jumps, with 2.03 per 1000 jumps requiring CASEVAC. Conclusions: Overall attrition rates of the steerable SF-10A parachute were below those of previously reported non-steerable parachutes, suggesting further evaluation is warranted of maneuverable parachutes in all military services.