SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Ikeda T, Okamoto Y, Hashimoto A. Aviat. Space Environ. Med. 1993; 64(2): 121-125.

Affiliation

Maritime Self-Defense Force, Undersea Medical Center, Yokosuka, Japan.

Copyright

(Copyright © 1993, Aerospace Medical Association)

DOI

unavailable

PMID

8431185

Abstract

To find the minimum supersaturation pressure for detectable bubble formation and for contraction of decompression sickness (DCS), three shallow air saturation dives at the depth of 6 m, 7 m, and 8 m were performed. The ultrasonic M-mode method was used for detecting bubbles. The exposure period was 3 d for all dives. Ten subjects were compressed to both 6 m and 7 m, and nine subjects were compressed to 8 m. One bubble streak was shown in the 6-m dive group. A small number of bubbles were seen in four subjects in the 7-m dive. All subjects in the 8-m dive presented various amounts of bubbles. DCS was not observed in the 6-m and 7-m dives. On the other hand, in the 8-m dive, four subjects suffered from DCS and required recompression treatment. The minimum depth for detectable bubble formation was assessed at around 6 m and the direct ascent from saturation at 8 m seems to have a high risk of DCS.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print