SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Bonsu AK, Stead AL. Anaesthesia 1983; 38(8): 767-769.

Copyright

(Copyright © 1983, Association of Anaesthetists of Great Britain and Ireland, Publisher John Wiley and Sons)

DOI

unavailable

PMID

6881500

Abstract

Oxygen and nitrous oxide pipes were cross-connected during the servicing of an anaesthetic machine. This resulted in the delivery of 100% nitrous oxide instead of 100% oxygen at the end of the operation. The patient fully recovered and was discharged on the 13th day.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print