Wells MJ, Griffin MJ. Aviat. Space Environ. Med. 1984; 55(1): 13-18.

Copyright

(Copyright © 1984, Aerospace Medical Association)

DOI

unavailable

PMID

6696690

Abstract

The effects of whole-body vertical vibration in the range 2.5-25 Hz on visual performance with two types of raster scan helmet-mounted display have been determined. The benefit of an image stabilisation system on numeral reading performance during vibration was also assessed with both display systems. Increases in mean reading time of over 130%/m . s-2 R.M.S. and increases in percentage reading error of more than 30%/m . s-2 R.M.S. were recorded with unstabilised displays. With vertical and horizontal image stabilisation, these decrements in performance were reduced to less than 40%/m . s-2 R.M.S. increase in reading time and less than 10%/m . s-2 R.M.S. increase in reading error. Data on the transmission of vibration from the seat to the head and from the head to the helmet were also obtained. These indicate a relation between biodynamic behaviour and visual performance during vibration.


Language: en