TY - JOUR
PY - 2020//
TI - The use of point-of-care testing to establish cause of death in the autopsy setting
JO - Journal of forensic and legal medicine
A1 - Ginn, Claire
A1 - Ateh, Davidson
A1 - Martin, Joanne
SP - e101933
EP - e101933
VL - 71
IS -
N2 - This review assesses the use of point-of-care testing (POCT) in establishing a cause of death in the autopsy setting. A search was performed of the PubMed, Medline, Embase, ScienceDirect and Scopus databases using the terms point-of-care, autopsy, post-mortem, cause of death and forensics. This search revealed some evidence for the efficacy of POCT for autopsy derived samples in the detection of viruses, sepsis and abnormal glucose levels. Other potential applications for forensic POCT include drug abuse screening, detection of alcoholic and diabetic acidoketosis and carbon monoxide poisoning. Additional studies are needed to evaluate to the accuracy of POCT compared to standard laboratory testing and to more fully understand post-mortem derived sample errors.
Copyright © 2020 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Language: en
LA - en SN - 1752-928X UR - http://dx.doi.org/10.1016/j.jflm.2020.101933 ID - ref1 ER -