TY - JOUR PY - 1995// TI - Fire Degradation of an Intumescent Flame-Retardant Polypropylene Using the Cone Calorimeter JO - Journal of fire sciences A1 - Bourbigot, S. A1 - LeBras, M A1 - Delobel, R SP - 3 EP - 22 VL - 13 IS - 1 N2 - This work studies the fire degradation of an intumescent formulation Polypropylene (PP)-Ammonium Polyphosphate (APP)/Pentaerythritol (PER) using the cone calorimeter. An intumescence model is described which introduces the notion of degradation front. From the weight loss data recorded by the cone calorimeter and the results of the invariant kinetic parameters method (given in appendix) applied to the PP and to the PP-APP/PER system, the respective temperatures of the degradation fronts are measured. A stability zone is shown where the protection is effective. The intumescent coating degrades then by forming a carbonaceous residue which reduces the heat flux evolved.

LA - en SN - 0734-9041 UR - http://dx.doi.org/ ID - ref1 ER -